| Step | Calculation | Result | |------|-------------|--------| | 1. Factored load | ( w_d = 1.5 \times 20 = 30 \text kN/m ) ( P_d = 1.5 \times 30 = 45 \text kN ) | — | | 2. Maximum moment | ( M_d = \fracw_d L^28 + \fracP_d L4 = \frac30 \times 6^28 + \frac45 \times 64 = 135 + 67.5 = 202.5 \text kN·m ) | — | | 3. Choose section | IS 2062 I‑250 (Ag= 12 900 mm², Iz= 2.5 × 10⁶ mm⁴) | — | | 4. Plastic moment | ( M_p = 0.66 f_y A_g Z = 0.66 \times 250 \times 12 900 \times 0.9 \approx 1 920 \text kN·m ) | (compact) | | 5. Design strength | ( \phi M_n = 0.9 \times M_p = 1 728 \text kN·m ) | — | | 6. ULS check | ( M_d = 202.5 \text kN·m \le 1 728 \text kN·m ) | | | 7. Deflection (SLS) | ( \Delta = \frac5 w L^4384 E I = \frac5 \times 20 \times 6^4384 \times 200 000 \times 2.5 × 10^6 \approx 7.5 \text mm ) | Limit L/250 = 24 mm → OK |

Disclaimer

We do not host, upload or link to any video, films, media file, live streams, etc. The Little Guys Co is not responsible for the accuracy, compliance, copyright, legality, decency, or any other aspect of the content streamed to/from your device. It is your responsibility to ensure that you comply with all your regional legalities and personal access rights regarding any streams to be found on the web.